We have 1 Bosch HydroPower TF325-8G(13H) manual available for free PDF download: Installation Manual And Operating Instructions. Continuous Flow Gas Water Heaters (External Models). Vertical Flue Kit, Installation Manual, Download (PDF MB). The Bosch 13H has a Star Energy Efficiency rating. Bosch HydroPower 13H Pdf User Manuals. OptiFlow Bluetooth OptiFlow Professional Models, Installation Manual, Download (PDF MB). Ask a question about Bosch HydroPower in Gas Water Heaters. I purchased this Bosch instant hot water unit to replace a gas storage water heater in order to save space and. Question About Bosch Appliances Water Heater 16H Hydropower. Installation should be pretty straightforward and the manual's not that in depth. There are however some sections on adjusting the gas and the like that you might want to read over.Login to post Now if needed clean over the whole unit with compressed air to spruce it up and reduce fire hazard or if your diy then it's nice to clean things before working on them imo. Don't ask me what all that would cost. You don't need to mess round with the gas side that's all fine. Now here's what you do to fix em, this is for a Bosch Hydropower 10H but I assume it probably applies to the other hydropower models too.Search: GWH 715 ES manual.pdf Adding.pdf to search parameter helps locate manuals. Sell sheet with venting overview, technical and product specs: Manual for ES high altitude, with installation, error codes and troubleshoot: I cannot find a service manual, or service bulletins: The suspect is probably gas supply, gas valve, or gas related part inside tankless unit. Before calling service technician, open following link for Bosch tankless troubleshooting resources, including Bosch contact information, typical manuals, error codes, tech support, parts, fuel-saver calculator, service bulletins, water heater forum, fixya links, disclaimers, and links for finding service technician.https://www.aimp.org/UserFiles/bosch-plena-matrix-manual.xml
Read manual cover to cover, make sure tankless receives yearly maintenance as outline in manual. Add a comment with your experience so others with same-similar problem can benefit. Also take advantage of fixya expert assistance live. For a price, expert works with you while you work on water heater or any do-it-yourself project. Fixya is always less expensive than a service call.The gas is turned on. Just moved into this house so new to the machine with no manual. Comes up with. Read manual cover to cover, make sure tankless receives yearly maintenance as outline in manual. Fixya is always less expensive than a service call.The unit suddenly has no spark.I have taken off the little generater cap and thouroughly cleaned it and the internal turbine. With no improvement. All. Installation should be pretty straightforward and the manual's not that in depth. There are however some sections on adjusting the gas and the like that you might want to read over.What is going on? Answer questions, earn points and help others. Can't get any hot water. Please help anyone. Like Share More 1 answer Good run 3 weeks ago Call a plumber.Turn the tap to max - if this does not work, then turn the tap off, wait 1 minute and turn it on to max as fast as you can.Do not try to turn the cold on at the same time until you have the hot working - and even when the hot works - be careful turning on the cold depending on your tap or shower attachments as this may slow the flow of hot enough to make the system shut down the burners again. Sit back and watch your water bill and gas bill go through the roof even though these systems claim to be energy efficient.Like Report James B. 5 months ago Your other option is to take the cover off. There are two user adjustable settings (at least on my 16H) - one shows 1 to 3 flame symbols - this is for adjusting the temperature from low to high flame.Like Report Ken K asked 7 months ago HydroPower 13H How do you restart the pilot light.http://www.tj.net.au/upload/bosch-plena-matrix-manual.xml
Like Share More 1 answer mrammelt 7 months ago You don't. When you turn the water on it spins a small generator that ignites the gas. These font have a pilot light. Will restart but goes out after 10 -15 seconds. Like Report Richie G asked 12 months ago HydroPower 13H how do you turn hot water temperature up Like Share More 3 answers Lucei 12 months ago Sorry but the unit is rubbish, I have had three plumbers in to try and get hot water but all say there is nothing they can do. They have contacted the Bosch technical team and spoken to them while they were here and the answer by the technical side was there was nothing more that could be done. The unit is useless. Like Report David 12 months ago We cannot turn the temperature up more than maximum on the unit, I have a shower on full heat. We have to turn the tap on a number of times to get the heater to work. I will never buy another Bosch product. Please be informed that a few alterations can be made to increase the hot water temperature. Inside the unit there are 2 temperature adjustments that can be made: a slide control that controls the gas burner and a round dial on the water valve. Slide the control to the right to increase the burner and temperature, you can also turn the round dial clockwise to increase the temperature. If these are already set to the maximum settings, then a service is required. Services are recommended every 2 years. If you need assistance with getting in touch with an approved service agent, please call us at 1300 30 70 37 any time between 7:30AM and 6PM (AEST) on a weekday. Like Report Carrie-Ann Starick asked 1 year ago HydroPower 13H Hi we have the hot water system listed in other question. Problem is: all burners are lit and stay lit but water doesn't get hot, only lukewarm. It is fed from gas bottles. System is around 4 years old. Have checked and there doesn't seem to be any blockages. We generally recommend that all hot water systems are serviced at least every two years.
If you require assistance in finding a Bosch approved service technician, please get in touch with our helpful team at 1300 30 70 37 and we’ll be able to find you a local solution. Our team is available from 7:30am to 6:00pm (AEST) Monday to Friday on our toll-free line. Like Report Ann asked 1 year ago HydroPower 13H No hot water. Looks like pilot light is out. How do you relight it and do you think that will be all that is wrong. Like Share More 3 answers Peter J 1 year ago Not familiar with the model. The H for Hydroflo in the model name usually means it has a Water Wheel igniter (no pilot light). I'd be calling who ever installed it to check out the electrics and the gas flow. If you follow the steps mentioned in the answer to your other question and it does not trigger your ignition, please get in touch with us at our toll-free number 1300 30 70 37. Our team is available from 8am to 6pm (AEDT) during the weekday and we will be able to put you in touch with a Bosch recommended service agent. We recommend ensuring that all your hot water taps are off before turning one tap back on at full flow. If this does not trigger your ignition, please isolate the valves at the unit for twenty seconds before re-opening them and trying the steps above again. If this does not work, please get in touch with us at 1300 30 70 37 from 8am to 6pm (AEDT). Please be advised that we do require more information such as the age of the unit, the gas type you are using, and whether it has been serviced recently. Our helpful team is available from 8am to 6pm (AEDT) from Monday to Friday and can be contacted free of charge at 1300 30 70 37. Like Report Gary Dorahy asked 2 years ago HydroPower 13H Slow water leak from underneath my TF325-8gng Hydro power Bosch13H natural Gas water heater. Please call our helpful team at our toll-free number 1300 30 70 37 any time during the weekday from 8am to 6pm (AEST).
If you would like us to get in touch with you, please fill out the following form:, referring to your issue by copying in the link to your review. Once we receive this information, we will contact you within a business day. Like Report Mod asked 2 years ago HydroPower 13H It wont light. As there could be variety of factors involved, we would recommend calling our helpful customer service team at our toll-free number 1300 30 70 37 any time from 8am to 6pm (AEST) during the weekday. Our team will be able to gain better insight to the problem and assist in correcting the issue. Like Report Brian 2 years ago I have the the same problem how did you fix it 1 like Report listengart asked 2 years ago HydroPower 13H hello. Like Share More No answers ALAN H asked 3 years ago HydroPower 13H I've been having a problem with my HydroPower 13. The pilot flame works and the gas burner comes on fine but only last for about 20 seconds and then goes out.Any help? Like Share More 4 answers bog balls 3 years ago Probably a dirty pilot jet. Remove the little aluminum pipe to pilot piezo. Its got brass 10mm nuts. Be careful the jet does not get lost it is at the top of pipe. Remove the jet (its as big as a babies fingernail) blow through it and wipe it in your shirt. Its the tiniest little hole and gets wax from dirty gas stuck in it. Put it back in and refit pipe. Try that. Like Report aheritage 3 years ago Thanks for the thought Bog Balls. The pilot flame seems to be OK.Like Report Hughesy 3 years ago I have the same problem. Did you find a answer mate Like Report View 1 more answer John asked 3 years ago HydroPower 13H Hi Re 13 H all was good and all of a sudden no clicking so no ignition, full gas bottle, plenty of water, can you advise? John. Like Share More 1 answer Gone a million 3 years ago Hi John. Typical fault. Water driven ignition module has failed you. Part and gasget is too expensive to replace and will only fail again and again. You have joined the club of Bosch junkers.
Spend your momey on a Rinnai infinity. Get the B26. Same heating specs as 26 just a few hundred cheaper and no led status light. Warranty a bit shorter as designed for builders who supply warranty on new home. Family will thank you. You have to learn to let go as you can't polish a turd. Learn by my mistake. 1 like Report Paul asked 4 years ago HydroPower 13H Having problems lately with our 13H where everytime the hot water is turned on (low demand.Like Share More 1 answer Baxy 4 years ago Paul Same problem I had the water that releases the pressure on the diaphragm for the main burner is not getting through. Follow the copper pipe that comes out of the hydro generator it comes back to the front of the appliance and goes into the housing mine is gray and has the knob that adjusts the flow. There is a metal u clip on top of where the pipe enters the housing pull it out the pipe will pull out and can be moved to the side. When I go out to the hot water service 13H I can hear a clicking noise which I assume is the unit trying to start up but it seems that there is not enough water pressure to cause it to light. However, like I said it's working when the hot water taps are turned on over the kitchen sink, shower and bath. Any suggestions? Like Share More 1 answer Baxy 4 years ago John Check if you have a flow restrict or in the basin spout or if it has flexible hoses connecting it may have a restrictor in the hoses pull the plastic restrictors out and throw at the cat. Good luck Baxy Like Report Annie D asked 5 years ago HydroPower 13H Thought I must have run out of gas as no hot water but gas bottle half full.I downloaded the manual, and it suggests cleaning the hydrogenerator as may be jammed but doesn't tell you how to do. Whether you love or loath being in the kitchen, our community of reviewers have determined that out of almost 5,000 appliances on ProductReview.com.au, these are the best available! Nathan S. Nov 01, 2019 Best Fridges and Dishwashers in 2020.
These large kitchen appliances are the backbone of your kitchen, meant to last you many years. The initial cost of a fridge or dishwasher is high, so to make sure you're not buying a lemon, here are the best fridges and best dishwashers of 2020. ProductReview.com.au has affiliate partnerships. The old 960 gas pilot ignition unit worked fine, but this one struggles with putting out a steady flow of hot water. Sometimes the burners turn off while shower is on, and getting the right temperature in shower is tricky. I know the flow rate is really low, and probably not enough to keep burners going once you start to mix the water, but I don't know where it is being restricted. Any clues as to what's going on and how to fix it. The added restriction caused by the Bosch in the hot water system can result in uneven pressures between the cold and the hot. In such cases when mixing cold water at the tap, the lower hot water pressure may be overpowered by a much higher cold water pressure, which may cause the Bosch burners to shut down. Does anyone have any ideas. Thanks, Johan The filter should be an easy fix but if it is an old unit and is badly scaled up, it might be toast. Poor little thing might be chugging it's guts out but it's just not enough! My Rinnai unit delivers a considerable stream of warm air out the 'flue' (just a slot on the front of the device, since the unit is mounted outside) when it's running. You could check that that is steady, when there's hot water draw. The fan is also easily audible. Never mind, if not). Never mind, if not). Ignition is achieved by a turbine that runs off the energy of the water flow. In most cases it appears that the complaints are caused by the installation being faulty in terms of inappropriate flow restrictors or pipeline lengths. It seems here that the OP's parents water lines or showerheads have excessively low flow rates. Anybody know a German plumber?
Possibly a blockage at the heater, in the HW feed or supply or at a tempering valve as others have suggested. It will assist in determining whether there is a restriction and its location. It is clean and shiny inside and the gas ignites well and can be adjusted with the knobs. I'm interested in the filter cleaning suggestion, but could not determine which is the actual part I'm meant to be looking at, as I could not find a diagram online or in the installation manual. Is there a reason why the flow in the kitchen would be greater than the flow to the bathroom tap and also shower tap. Thanks again! Sorry, replied to posts without refreshing page so hadn't read these last few. Tempering valves have strainers that can be blocked from dirt etc. The strainers are usually cleanable. BTW turning on another tap is for testing purposes only to determine if there is a restriction and where it might be located. eg. If turning on the basin tap makes no difference and the basin and shower are supplied via the same tempering valve it is most likely the tempering valve causing the restriction. It just seemed like the most appropriate place to seek help. I have done a bit of Googling to find the relighting process for our model of water heater (Bosch HydroPower 16H) but am coming up short on answers. It does have a lockout mechanism if it fails to ignite. Turn off the isolation hot water near or on the unit.Wait 1 minute. Turn on hot water again. Starting with the isolation. Something went wrong.Learn more - opens in a new window or tab This amount is subject to change until you make payment. For additional information, see the Global Shipping Program terms and conditions - opens in a new window or tab This amount is subject to change until you make payment. If you reside in an EU member state besides UK, import VAT on this purchase is not recoverable.
For additional information, see the Global Shipping Program terms and conditions - opens in a new window or tab Learn more - opens in a new window or tab Learn more - opens in a new window or tab Learn more - opens in a new window or tab Learn more - opens in a new window or tab Learn more - opens in a new window or tab See the seller's listing for full details. Contact the seller - opens in a new window or tab and request postage to your location. Please enter a valid postcode. Please enter a number less than or equal to 66. If you don't follow our item condition policy for returns, you may not receive a full refund. Refunds by law: In Australia, consumers have a legal right to obtain a refund from a business if the goods purchased are faulty, not fit for purpose or don't match the seller's description. More information at returns. Works great. Good quality and works well. All Rights Reserved. User Agreement, Privacy, Cookies and AdChoice Norton Secured - powered by Verisign. HydroPower. Installation Manual and Operating Instructions. Read installation manual prior to installation of this unit! Read user manual before putting this unit in operation! Observe the warnings in the manuals! The installation room must fulfill the ventilation requirements! Installation by an authorised person only! Table of contentsWarnings. Warnings in this document are identified byKeywords at the start of a warning indicateThe following keywords are defined and used in this document:Important information. This symbol indicates important informationAdditional symbols. Symbol ExplanationList entry. List entry (second level). Table 1If you smell gas:HydroPower. If you notice dark combustion gases or sooting:Installation, Assembly and ModificationsMaintenanceExplosive and highly flammable materialCombustion air and surrounding airRisk of damage due to operator error. Operator errors can result in injury and damage to property.To be installed and serviced only by an authorised person.
The “authorised installing person” is responsible for:Models. CategoryTF (Top Flue). G (Hydrogenerator). TF (Top Flue). Table 3Water filter on the inlet water supply. Economical. Only heating water when required, the Bosch range isVersatile. LPG models are particularly popular in country areas, where. Natural Gas is not available. Low Temperature AreasPackage contents. Gas hot water unit. DocumentationHydroPower Ignition is exclusive to Bosch - it does not requireHydroPower uses the energy created by the water flow toOnce the tap isHot Water Unit for external wall-mounting only. Available in Natural gas or LP gas. Hydrogenerator produces sufficient energy to ignite andSafety devices. Fig. 1. EXOGEL valve. Low Flow Rates. This gas water heater is designed to operate at a minimum flowThere are various causes of a low flow rate including, but notWater fixtures with a flow rate of 7.5 litres per min for handFailure of the unit to operate correctly due to poor flow rate willHydroPowerTop flue. Front cover. Inspection window. Wall mounting point. Cold water inlet. Gas inlet. Hot water outlet. Dimensions (mm)Dimensions. HydroPowerTemperature limiter. Hydrogenerator. LED (green). LED (red). UnitsDiaphragm Switch. Pilot Solenoid Valve. Ionisation electrode (Flame Rod). Ignition electrode (Spark Electrode)Technical characteristics. Gas Consumption. Nominal Gas Consumption. Supply pressure flowing. Number of injectors. Water data. Maximum permissible pressure (Static)Temperature selector in fully clockwise position. Temperature rise (Above incoming water temperature)Minimum operating water pressureTable 5. Technical characteristics. Units. Temperature selector in fully anti-clockwise position. Temperature rise (Above incoming water temperature). Water flow range (Litres per minute)Minimum operating water pressureNOTICE: Property damage! If the appliance is to be installed on aRegulations.
All local by-laws and regulations pertaining to installation andThis appliance must be installed in accordance with the. This appliance must not be installed indoors or in an enclosedDo not install this appliance with any modification or alteration.Failure to install this appliance in accordance with theseDANGER: Explosion Risk!DANGER: Appliance malfunction! This appliance must be installed with noHeat shield. The installation and the initial startup are toNot suitable for pool, spa pool, or solarNot suitable for commercial boosting of aThis appliance should only be installed inHydroPower. Minimum water supply pressure must meetWater fixtures with a flow rate of 7.5 litresTo reduce the chance of corrosion,All gas appliances require adequate airPest and dirt ingress is not covered by theThis test must beNote: Incorrect pipe sizing or gas supply pressure may causeService calls for incorrect pipeImportant informationIf the unit is to be installedThe preferableHydroPowerComply with the specific instructions for each State. Install the appliance in an outdoor location where it will notInstall the appliance in accordance with the minimumThe gas heater must not be installed over a heat source. Do not obstruct the openings at top, bottom and rear ofMaximum of 2 meters from the ground to the base of theTop and bottom areas must be clear from any obstacles atOpenable Door. Flue terminal. Gas meter. Mechanical air inlet. Electricity meter or fuse box. Openable window. MinimumRef. ItemBelow eaves, balconies and other projections:Combustion gasesFig. 6. Heater mounting. HydroPowerThe gas pressures require setting upon installation.Water connection. Purge the water pipes before connection, because thePressures to complete appliance commissioning.Fig. 7. Water connectionValve, Duo Valve or Non-Return Valve mustIncorrect gas pipe sizing will not be coveredFront cover removal. Gas regulator.
The appliance is supplied with a gas pressure regulator alreadyHydroPowerGas pressure adjustment (commissioning) MUST be carriedStatic Pressures should be greater than or equal to the figuresAdjust the appliance regulator to achieve the figures in table 7If the operating inlet pressure cannot be achieved there may beThis must be resolvedMaximum gas flow adjustmentRight (maximum gas flow).Measurements should be made with unitIf possible all other gas appliances (ductedNatural gas. LP gasTable 7Max. Burner. Pressure (kPa). Table 8. Natural gas. LP gasMinimum gas flow adjustmentBurner pressure adjustmentHydroPowerFig. 12For higher water temperature (Fig. 13). Slide to the right will give higher water temperature but useFig. 13Increases flow and decreases water temperature (Fig. 14). Minimum gas flow adjusting screw. LP gasPressure (kPa). Table 9Conversion to a different type of gas. It is not recommended to convert these units to a different typeFor lower water temperature (Fig. 12). Slide to the left will give lower water temperature and use lessFig. 14Decreases flow and increases water temperature. Regulating the temperature to the minimum required valueThe LED light is not normally visible with the cover on, howeverIf the red LED is flashing this indicates a fault condition andHydroPowerTo ensure ongoing performance and safety, we require theMaintenance must only be performed by aMaintenanceHydroPowerThe following chart offers possible solutionsIn most instances it is advisable to have a technician attend and inspect the appliance. Some further trouble shooting advice may be found at. Problem. Cause. Solution. Fluctuation in hot water temperature. Insufficient flow through the hot waterIncrease water flow by opening multipleIf fluctuation ceases then check forTapware does not give sufficient flowChange tapware to meet requirements. Unit not working. (No Hot Water). Locked out due to failure to ignite. Turn off all hot water taps and retry.
The ignition will lock out after 20 seconds If unit still does not work - isolate valves atIf unit still fails to ignite refer to qualifiedUnit not working after change in Gas. Supply (Maintenance work on Mains orAir in gas lines. Turn on hot water tap inside house. Isolate water valve at unit for 20 seconds. Open valve and check if unit lights. Repeat this operation 3-4 times, if unitNot hot enough. Insufficient Natural Gas supply. Requires a service technician to inspectConsumer gas and water controls. Adjust gas and water controls.Smell of gas. Gas leak.Call your Gas Retailer or a qualifiedTemperature too hot in Summer. Incoming water temperature hasAdjust Water and Gas controls at the unitTemperature too cold in Winter. Incoming water temperature hasAdjust Water and Gas controls at the unitTable 10. Reduced water flow. Insufficient water supply pressure. Dirty taps or mixers. Water valve blocked (filter). Heat exchanger blocked (limescale). Requires a service technician to inspectUnit makes a loud bang when igniting. Explosive ignition is not normalCall a qualified technician. This is normally caused by blockages inOne of the causes of blockages is insectsAll gas appliances require adequate airThe ingressThe unit will needTo minimise the chance of the issueIsolate the valves to the unit and sprayLeave for 15 minutes before turning hotWater takes a long time to reach hot taps. Location of unit. If the unit is located a long way from theAs the hot waterOpen hot tap to full to increase flow rateTable 10Environmental protection is a basic company strategy of. Bosch. The quality of our products, profitability andOld appliances. Old appliances contain valuable materials that should bePackaging.
We participate in the recycling program of the respectiveAll of our packagingHydroPowerAll Bosch water heating appliances are constructed from highWhile Bosch water heaters are warranted againstIn the case of the waterIn areas of Australia and New Zealand where water may beWhere uncertainty exists concerning water quality, intendingWater quality table. Maximum levelsSaturation. Index(LSI). TotalHydroPowerRobert Bosch (Australia) Pty Ltd. Thermotechnology Division. Voluntary Repair or Replacement Warranty. All Bosch products are carefully checked, tested and certified to Australian and New Zealand standards. Important Note: Mandatory Australian Consumer Law statement. If you have purchased your product in Australia, you should be aware that. This warranty is provided in addition to other rights and remedies held by a consumer at law. Our goods come with guarantees thatYou are entitled to a replacement or refund for a major failure and forYou are also entitled to have the goods repaired or replaced ifImportant Note: New Zealand law. If you have purchased your product in New Zealand, you should be aware that. This warranty is supplemental to any other rights and remedies you have under the Consumer Guarantees Act 1993 NZ, unless yourGuarantees Act 1993 NZ in respect of your product. Warranty. Bosch warrants, at its option, to repair or replace your water heater or relevant part thereof (Product) if such Product are faulty orThe warranty period commences on the date of purchase. If the date of original purchase cannot be determined, then the warrantyBosch may require evidence to verifyThis warranty only covers repair or replacement of defective Product (including labour costs where indicated). It does not cover:Mandatory Australian Consumer Law statement” above. Warranty Period and Coverage. Bosch will provide warranty service for Product purchased and installed in Australia and New Zealand as follows.
The period after purchase within whichWhat Bosch will do (see below forAll components. Heat exchanger. Parts only. All components. Components. Domestic Use (see below for definition). Commercial Use (see below for definition). Table 12. All installation and repair labour costs are the responsibility ofHydroPower. Product used for all other uses, the commercial use warranty period will apply. This includes, without limitation, installations suchFor “Parts only” warranty, the end user will be charged for service call costs and service technician fees in effecting the replacement.If the Product is not located within the usual operating area of an authorised service technician, the end user will be required to payNotwithstanding the above, if the Product has not been installed in accordance with the installation instructions in regards toThis includes, but is not limited to, the removal of walls or doors to gain access and the use ofWhere the Product cannot be safely accessed. Bosch may refuse to service the Product under this voluntary warranty. For invalid claims under this voluntary warranty, the end user will be liable for the costs of making the warranty claim including anyWarranty Conditions. This voluntary warranty is subject to the following conditions:Proof may be required of correct commissioning of the Product (such asClaims for failures due to incorrect installation or commissioning are not covered under thisWarranty Exclusions. This warranty will not apply to a defect or fault to the extent to which it arises:HydroPowerProduct. This voluntary warranty does not apply to damage that has been caused by continued use of a Product after it is known, or wouldFailure to service Product in accordance with recommendations in instruction manuals for Product may result in a warranty claimBosch alerts end users that instruction manuals for Product containTable 13. Wrong Deliveries and Transit Damage.